 PRODUCTION ERRATA PMC-2001737 ISSUE 1
PM5342 SPECTRA-155
SONET/SDH PAYLOAD EXTRACTOR/ALIGNER ERRATA
PM5342
SPECTRA-155
SONET/SDH PAYLOAD EXTRACTOR/ALIGNER
REVISION E DEVICE ERRATA
ISSUE 1: NOVEMBER 2000 PRODUCTION
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA INC., AND FOR ITS CUSTOMERS' INTERNAL USE
PRODUCTION ERRATA PMC-2001737 ISSUE 1
PM5342 SPECTRA-155
SONET/SDH PAYLOAD EXTRACTOR/ALIGNER ERRATA
REVISION HISTORY
Issue No. 1 Issue Date November 2000 Details of Change Document created.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA INC., AND FOR ITS CUSTOMERS' INTERNAL USE
PRODUCTION ERRATA PMC-2001737 ISSUE 1
PM5342 SPECTRA-155
SONET/SDH PAYLOAD EXTRACTOR/ALIGNER ERRATA
CONTENTS 1 ISSUE 1 ERRATA ..................................................................................2 1.1 2 3 DEVICE IDENTIFICATION ..........................................................2
FUNCTIONAL DEFICIENCIES OVERVIEW ..........................................3 SPECTRA-155 REVISION E FUNCTIONAL DEFICIENCY DETAILS ................................................................................................4 3.1 DEVICE RESET/RECONFIGURATION.......................................4 3.1.1 FIFO LOCKED IN OVERFLOW/UNDERFLOW CONDITION .....................................................................4
4
SPECTRA-155 REVISION E DATASHEET ERRATA.............................6 4.1 4.2 DISV1 BIT DESCRIPTION CORRECTION - PAGE 336 ..............................................................................................6 RTIMINS AND RTIUINS BIT DESCRIPTION CORRECTION - PAGE 195........................................................7
5
CONTACTING PMC-SIERRA, INC ........................................................8
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA INC., AND FOR ITS CUSTOMERS' INTERNAL USE
i
PRODUCTION ERRATA PMC-2001737 ISSUE 1
PM5342 SPECTRA-155
SONET/SDH PAYLOAD EXTRACTOR/ALIGNER ERRATA
1
ISSUE 1 ERRATA This document is the errata notice for Revision E, production release of the SPECTRA-155 (PM5342-BI) and issue 4 SPECTRA-155 datasheet. The issue 4 SPECTRA-155 datasheet (PMC-1970133) and issue 1 errata supersede all prior editions and versions of the datasheet.
1.1
Device Identification The information in this document applies to the PM5342 SPECTRA-155 revision E device only. The device revision code is marked at the end of the Wafer Batch Code on the face of the device (as shown in Figure 1). PM5342 SPECTRA-155 Revision E is packaged in a 256 pin Super BGA package.
Figure 1: PM5342 SPECTRA-155 Branding Format
Pin A1 Index Mark PMC Logo
SPECTRA Logo
TM
SPECTRA-155
PM5342-BI C E Myyww
TOP VIEW SCALE : 2:1 (APPROX.)
Part Number Wafer Batch Code Assembly Date Code
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA INC., AND FOR ITS CUSTOMERS' INTERNAL USE
2
PRODUCTION ERRATA PMC-2001737 ISSUE 1
PM5342 SPECTRA-155
SONET/SDH PAYLOAD EXTRACTOR/ALIGNER ERRATA
2
FUNCTIONAL DEFICIENCIES OVERVIEW This section outlines the known functional discrepancies between the PM5342 SPECTRA-155 revision E production release device and the Issue 4 SPECTRA155 datasheet. The errata are explained in more detail in section 3 of this document. Please note that the errata contained in this document are preliminary.
Table 1 FUNCTIONAL DEFICIENCIES SUMMARY LIST
# Discrepancy 3.1 Device Reset/Reconfiguration 3.1.1 FIFO Locked in Overflow/Underflow Condition Workaround? Yes Modes Affected Reset/Reconfiguration
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA INC., AND FOR ITS CUSTOMERS' INTERNAL USE
3
PRODUCTION ERRATA PMC-2001737 ISSUE 1
PM5342 SPECTRA-155
SONET/SDH PAYLOAD EXTRACTOR/ALIGNER ERRATA
3 3.1
SPECTRA-155 REVISION E FUNCTIONAL DEFICIENCY DETAILS Device Reset/Reconfiguration
3.1.1 FIFO Locked in Overflow/Underflow Condition Description The SPECTRA-155 device may exhibit a failure where the Elastic Store FIFO in the RTAL or TTAL blocks does not recover normally from an underflow or overflow caused by a hardware or software reset, or service-affecting event. Most of the time, the FIFO will recover automatically from overflow or underflow conditions. However, there is a small probability that the FIFO will not recover by itself and will need to be manually reset. The rate of failure varies from 0% to 1%. Service-affecting events include LOS, LOF, AU-LOP, AU-NDF, and AU-AIS. If this failure occurs, data will be corrupted and the ESEI bit in the RTAL or TTAL Interrupt Status and Control register will be set high continuously. Please note that the same symptoms will occur if there are board-level problems with the Telecom bus signals generated externally to SPECTRA-155. If the external system is generating Telecom bus inputs for SPECTRA-155 that are incorrect, the ESEI bit in the RTAL or TTAL will be set high continuously and data will be corrupted. When these symptoms are the result of incorrect input signals from the external system, resetting the internal FIFO will not solve the problem. Users who see these symptoms very frequently, particularly while a board is being debugged, should first verify that all Telecom bus input signals meet the specified timing requirements. This includes confirming that the ACK and DCK clocks are the proper frequency and that the AC1J1V1, APL, and DFP input signals are correct according to the specifications in the data sheet. Please contact PMC-Sierra Applications (apps@pmc-sierra.com) for assistance in debugging board-level Telecom bus timing issues. Workaround To verify that the device is in the failure condition: 1. After reset/reconfiguration or service-affecting event, read the ESEI bit in the RTAL and TTAL Interrupt Status and Control registers 141h, 181h, 1C1h, 129h, 169h, and 1A9h.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA INC., AND FOR ITS CUSTOMERS' INTERNAL USE
4
PRODUCTION ERRATA PMC-2001737 ISSUE 1
PM5342 SPECTRA-155
SONET/SDH PAYLOAD EXTRACTOR/ALIGNER ERRATA
2. Read the registers at least twice, waiting 500 us (minimum) between reads. If ESEI is high on the second read, and if there are no timing problems on the Telecom bus, the FIFO is in the failure condition and needs to be reset. Note: for STM-1/AU4 mode, read registers 141h and 129h only; for STM1/AU3 mode, read all listed registers. To reset the FIFO: 3. Reset the FIFO by toggling the Reserved bit 7 in the RTAL and TTAL Control registers corresponding to the affected RTAL/TTAL (Register 140h, 180h, 1C0h, 128h, 168h, and/or 1A8h). Hold the Reserved bit 7 high for 10 us (minimum) to ensure clean reset of the FIFO, then clear the bit. 4. After clearing the Reserved bit, wait 250us (minimum) to allow the FIFO to start up again. Repeat the reads of the ESEI bit in the affected RTAL/TTAL as described in Steps 1 and 2, to confirm that the ESEI bit clears. Performance without workaround If the failure occurs, the FIFO will remain locked in the overflow/underflow condition until it is reset. Data will continue to be corrupted. AIS-P will be inserted if it is enabled due to FIFO overflow/underflow conditions. The FIFO lock condition can occur only after a reset/reconfiguration or serviceaffecting event. Once the FIFO is operating properly, this failure will not occur during normal operation. If the above symptoms occur during normal operation, particularly while the board is being debugged, they are probably due to boardlevel problems with Telecom bus signals generated by the external system.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA INC., AND FOR ITS CUSTOMERS' INTERNAL USE
5
PRODUCTION ERRATA PMC-2001737 ISSUE 1
PM5342 SPECTRA-155
SONET/SDH PAYLOAD EXTRACTOR/ALIGNER ERRATA
4
SPECTRA-155 REVISION E DATASHEET ERRATA This section contains errata in the issue 4 SPECTRA-155 datasheet. 1. unaltered text is unchanged to add context to changes 2. new material is bold and italicized 3. comments specific to this document are in italics
4.1
DISV1 bit description correction - page 336 The DISV1 bit description should be modified as shown below: DISV1: When set high, the DISV1 bit configures the DC1J1V1, and GC1J1V1 outputs to mark only the frame and synchronous payload envelope (virtual container) alignments (C1 and J1 bytes). DC1J1V1 and GC1J1V1 will not indicate the tributary multiframe alignment. When DISV1 is set low, DC1J1V1 and GC1J1V1 mark all three of the frame, payload envelope and tributary multiframe alignments. It is recommended that DISV1 be set high in normal operation to disable the V1 pulse on DC1J1V1. PMC-Sierra's tributary-processing devices (PM5362 TUPP+, PM5363 TUPP+622, PM5365 TEMAP, and PM8315 TEMUX) interpret the H4 byte in the path overhead to identify the tributary multiframe alignment, so they do not require the V1 pulse. In applications that do not use tributaries, there is no definition for multiframe and therefore no need for the V1 pulse on DC1J1V1. The DISV1 bit must be set high when byte or nibble data mode as selected by the SMODE[2:0] inputs is in operation. The DISV1 bit must also be set high when the built-in DROP bus PRBS generator and monitor are used.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA INC., AND FOR ITS CUSTOMERS' INTERNAL USE
6
PRODUCTION ERRATA PMC-2001737 ISSUE 1
PM5342 SPECTRA-155
SONET/SDH PAYLOAD EXTRACTOR/ALIGNER ERRATA
4.2
RTIMINS and RTIUINS bit description correction - page 195 The RTIMINS and RTIUINS bit descriptions in register 1Dh currently read: This bit is active only when the ALLONES bit in the RLOP Control/Status register is set high; it is ignored if the ALLONES bit is set low" This description should be modified to read: This bit is active regardless of the state of the ALLONES bit in the RLOP Control/Status register
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA INC., AND FOR ITS CUSTOMERS' INTERNAL USE
7
PRODUCTION ERRATA PMC-2001737 ISSUE 1
PM5342 SPECTRA-155
SONET/SDH PAYLOAD EXTRACTOR/ALIGNER ERRATA
5
CONTACTING PMC-SIERRA, INC PMC-Sierra, Inc. 105-8555 Baxter Place Burnaby, BC Canada V5A 4V7 Tel: (604) 415-6000 Apps Support: (604) 415-4533 Fax: (604) 415-6200 Document Information: Corporate Information: Application Information: Web Site: document@pmc-sierra.com info@pmc-sierra.com apps@pmc-sierra.com http://www.pmc-sierra.com
None of the information contained in this document constitutes an express or implied warranty by PMC-Sierra, Inc. as to the sufficiency, fitness or suitability for a particular purpose of any such information or the fitness, or suitability for a particular purpose, merchantability, performance, compatibility with other parts or systems, of any of the products of PMC-Sierra, Inc., or any portion thereof, referred to in this document. PMC-Sierra, Inc. expressly disclaims all representations and warranties of any kind regarding the contents or use of the information, including, but not limited to, express and implied warranties of accuracy, completeness, merchantability, fitness for a particular use, or non-infringement. In no event will PMC-Sierra, Inc. be liable for any direct, indirect, special, incidental or consequential damages, including, but not limited to, lost profits, lost business or lost data resulting from any use of or reliance upon the information, whether or not PMC-Sierra, Inc. has been advised of the possibility of such damage. (c) 2000 PMC-Sierra, Inc. PMC-2001737 (R1) Ref PMC-1970133 Issue date: November 2000
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA INC., AND FOR ITS CUSTOMERS' INTERNAL USE
8